Heat Soak Test

To prevent this from happening, as in the photo above, we recommend taking the Heat Soak test.

- Why do you need a Heat Soak test?
- To minimize the risk of spontaneous fracture of tempered glass due to small inclusions of nickel sulfide (NiS), as well as possible problems with façade collapse, new installation, and also the costs of climbers.

- How did NiS get into the glass?
- During the production of float glass, nickel sulfide, barely visible to the human eye, can enter the charge.

- How can something so small destroy large glass?
- NiS only destroys tempered glass. During the quenching process, the small sulfide expands to critical sizes. During sudden cooling, it does not have time to return to its previous state. As a result, during operation, glass, unable to withstand such intense passions (tension) within itself, can spontaneously collapse.

Heat Soak Test is a method of artificially aging glass that allows you to identify the invisible monster in the early stages. Tempered glass is slowly heated to a temperature of 290oC and kept at this temperature for 6-8 hours. The glass is then slowly cooled. Glass that passes this test is not subject to self-destruction.