RGC continues to develop technologies that have the potential to change the face of cities. This time the company was faced with the task of creating an innovative solution for the facade, in which the double-glazed window could be located in an L-shape, going around the corner of the room. At the same time, it was necessary to preserve the overview, aesthetic appearance and characteristics of the double-glazed window in terms of insolation, thermal conductivity, resistance to wind loads, etc.
Standard path
There is already a standard solution: two double-glazed windows are glued into an aluminum frame perpendicular to each other, with one of them overlapping the other by about 10 cm.
This design is stable thanks to a power beam that runs from the window sill to the top of the frame. At the same time, the aesthetics from the outside are preserved due to the visual effect: from a distance, the power beam looks thin and does not stand out against the background of the other windows. But inside the room, the thickness is perceived live: it is about 10-15 cm. Therefore, the viewing angle from the building to the street is partially blocked.
Unique solution
We decided to improve the design and developed a new, unique system for connecting two glasses at an angle of 90 degrees. With this solution, looking at the street from the room, you will not see any bulky seams at the junction of the double-glazed windows, only a strip 3 mm thick.
There is also not only a visual, but also a constructive advantage: our corner glass unit is solid! This is a single camera in the shape of the letter “L”.
Sealed seam
The 90 degree glass fastening system requires a certain strength to withstand all standard loads. We have calculated a reliable sealed seam design using butyl and silicone. Installing such a system in a profile is not difficult.
Exact specifications and assembly
The corner glass unit we have developed can be either single-chamber or double-chamber. Its standard dimensions are: height - 3 m, width of each side of the corner - 1 m. Such dimensions are most in demand in construction. Inside there is the usual argon filling and triplex glass.
Assembly of one such double-glazed window, if it is double-chamber, occurs manually within 4 days.
First, glass blanks are made for the right and left walls.
Next, the glass is glued together at an angle of 90 degrees.
The first chamber is assembled and sealed.
The second chamber is assembled and sealed.
Near future
Climatic tests of this double-glazed window have been ongoing for about a year under factory conditions. They show that the system is resilient to various loads over time. Ahead - certification with confirmation of durability and a bright future for this unique corner structure.